NTS...WOEU TENAX®-T, TENAX®-TT, TENAX®-TZ, TENAX®-N

ntswoeu-tenax-t-tenax-tt-tenax-tz-tenax-nTrailing cable according to DIN VDE 0250, Part 813

Technical data: NTS...WOEU TENAX®-T, TENAX®-TT, TENAX®-TZ, TENAX®-N


CONSTRUCTION
1. Flexible tinned copper conductor, class 5
2. Core insulation of rubber compound of type 3GI3 based on EPR
3. Inner semi-conducting layer – up to 6 kV. It is completed with outer semi-conducting layer above 6 kV (these two semi-conducting layers form together with insulation a void free (homogeneous) radial field)
4. Inner sheath of synthetic rubber of type GM1 b
5. Outer sheath of chlorinated rubber compound of type 5GM3, oil resistant, self-extinguishing

A. Working core
B. Earth conductor can be incorporated as fourth core or distributed inside outer interstices. In special cases, e.g. for use with dredgers or as emergency cables, the earth conductor is distributed and located over outer semi-conducting layers (TENAX®-N).

Application
For connection of large mobile equipment e.g. excavators, stowing machines, full-portal gantry cranes etc.
Used under very high mechanical load, in dry or damp locations, also in areas with high risk of explosion, namely in open pit and underground coal mines, salt and metal mines, gravel and sand quarries, limestone mines, shipyards and ports, container terminals, heavy industry,
metallurgical plants and at construction sites.

TECHNICAL SPECIFICATION

Rated voltage U0/U:
0.6/1 kV, 1.8/3 kV, 3.6/6 kV, 6/10 kV, 8.7/15 kV,
12/20 kV, 14/25 kV, 18/30 kV, 20/35 kV
Bending radius: < 1 kV > 1 kV
- fixed installation min. 4 x D min. 6 x D
- on drums min. 6 x D min. 12 x D
- on deflection pulleys: min. 7.5 x D min. 15 x D
- flexing min. 5 x D min. 10 x D
Temperature range:
- fixed installation min. -40 °C max. +80 °C
- flexing min. -25 °C max. +80 °C
Colour of sheath: red

ALTERNATIVE CONSTRUCTIONS

TENAX®-TT
With torsion protection for guiding systems, which have deflection in several planes or reel axis parallel with travel direction.
TENAX®-TZ
With tensile release and improved flexibility for use under extra tensile stress.
TENAX®-N
As an emergency supply cable with permanent protection against accidental contact between inner and outer sheath. A special type with braided armour for tensile and compression load at trailing operations and with water-tight inner sheath for continuous operation in water is available.