UC300 26 Cat.5e U/UTP

uc300-26-cat.5e-u-utp100 Ω Data Cable ISO/IEC 11801 Cat.5e

Technical data:  UC300 26 Cat.5e U/UTP

Construction
1. Conductor stranded bare copper wire ∅ 0.48 mm (AWG 26)
2. Insulation Polyethylene, ∅ 0.9 mm
3. Twisting 2 cores to the pair
4. Cable lay up 4 pairs to the core
5. Sheath PVC or FRNC, grey RAL 7035

Technical specification
Bending radius:
≥ 20 mm without load
≥ 40 mm with load
Temperature range during operation: –20 °C up to +60 °C
Temperature range during installation: 0 °C up to +50 °C

Application: Tertiary (Horizontal)
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

Standards:
EIA/TIA 568A; ISO/IEC 11801 2nd ed.; IEC 61156-6; EN 50173-1; EN 50288-3-2

Fire rating
PVC: IEC 60332-1
FRNC: IEC 60332-1; IEC 60754-2; IEC 61034

Electrical Properties (at 20±5 °C)
DC loop resistance: ≤ 260 Ω/km
Resistance unbalance: ≤ 3 %
Insulation resistance (500 V): ≥ 2 000 MΩ∙km
Capacitance at 800 Hz: nom. 48 nF/km
Capacitance unbalance (pair to ground): ≤ 1 500 pF/km

Declaration of Conformity: UC300 cat.5e