JAMAK
Technical data:
JAMAK
CONSTRUCTION
1. Conductor Stranded tinned copper
2. Insulation PE
3. Unit Twisted and individually with, plastic-aluminium tape shielded pair, earth conductor and a number tape
4. Shield Plastic- aluminium tape with earth conductor
5. Sheath Grey LINYL-PVC
TECHNICAL SPECIFICATION
Bending radius:
during installation, min. 15 x D
during operation, min. 10 x D
Installation temperature min.: -5 °C
Max. operation temperature: +70 °C
Application:
- Fixed indoor installations
- Automation
- Instrumentation
- Process control
- Audio systems
- Suitable for MaxiTermipoint connections
Suitable specially for digital and low level analog signal transmission. The construction gives an excellent protection against electromagnetic interferencies.
Fire performance: The cable fulfils the fire condition requirements of IEC 332-1 (Flame retardant).
Identification: Pairs marked with numbers, a-conductors are orange and b-conductors are white.
JAMAK is also available as halogenfree (JAMAK-HF) and more effectively shielded (JAMAK-C) version.